- homeHome chevron_right
- Fire & Safety chevron_right
- Addressable Analogue Devices chevron_right
- Enea Series Detectors chevron_right
- Enea Series
Enea Series Detectors
Addressable analog detectors. Thanks to modern technologies based on the latest generation of microprocessors, they represent the most advanced fire detection systems available today.
Compatible with
Compatible with
ED100 optical smoke detector: adjustable sensitivity and high reliability with false alarm protection
The ED100 smoke detector from the Enea series utilizes the Tyndall effect (light scattering) to providehighly accurate detection of particles generated by a fire. Its ability to respond quickly makes it ideal for environments where early detection is crucial. The optimized design of the detection chamber, the superior sealing, and the 500-micron insect screen ensure excellent protection against false alarms. Furthermore, the detector’s sensitivity can be easily adjusted to different operating conditions, thanks to four selectable levels (0.08, 0.10, 0.12, 0.15 dB/m).
ED200 heat detector: versatile, precise and ideal for demanding environments
The Enea ED200 series detector is designed to ensure accurate temperature detection, even in conditions where smoke can cause false alarms. It can be configured in various operating modes (A1R, B, A2S, BR) with fixed thresholds between 58°C and 72°C and thermal velocity measurement capabilities. This versatility makes it particularly suitable for industrial environments, professional kitchens, or mechanical rooms, where optical detection may prove ineffective. The ED200 represents a reliable solution for thermal monitoring of sensitive areas.
ED300 dual-technology detector: enhanced safety and false alarm prevention
The Enea ED300 model combines optical smoke detection with thermal detection, delivering high performance in any type of fire scenario. With five operating modes selectable from the control panel (PLUS, OR, AND, SMOKE ONLY, TEMPERATURE ONLY), the device adapts perfectly to a variety of safety requirements. PLUS mode ensures maximum sensitivity for critical fire outbreaks, while AND mode offers maximum rejection of false alarms. The ED300 is the ideal choice for environments where high standards of reliability and operational flexibility are required.
This product is available in the following versions






Technical specifications
| ED100 | ED100/B | ED200 | ED200/B | ED300 | ED300/B | |
| Power supply voltage | 10 - 30 Vdc | 10 - 30 Vdc | 10 - 30 Vdc | 10 - 30 Vdc | 10 - 30 Vdc | 10 - 30 Vdc |
| Current draw during standby | 90 μA | 90 μA | 90 μA | 90 μA | 90 μA | 90 μA |
| Current draw during alarm | Max 40 mA | Max 40 mA | Max 40 mA | Max 40 mA | Max 40 mA | Max 40 mA |
| Adjustable sensitivity | 0.08 - 0.10 - 0.12 - 0.15 dBm | 0.08 - 0.10 - 0.12 - 0.15 dBm | 0.08 - 0.10 - 0.12 - 0.15 dBm | 0.08 - 0.10 - 0.12 - 0.15 dBm | 0.08 - 0.10 - 0.12 - 0.15 dBm | 0.08 - 0.10 - 0.12 - 0.15 dBm |
| Operating temperature | -5° ... +40°C | -5° ... +40°C | -5° ... +40°C | -5° ... +40°C | -5° ... +40°C | -5° ... +40°C |
| Height (including base) | 46 mm | 46 mm | 54 mm | 54 mm | 54 mm | 54 mm |
| Diameter | 110 mm | 110 mm | 110 mm | 110 mm | 110 mm | 110 mm |
| Weight (with base) | 160 g | 160 g | 160 g | 160 g | 160 g | 160 g |
| Weight (without base) | 90 g | 90 g | 90 g | 90 g | 90 g | 90 g |
| Colour | White | Black | White | Black | White | Black |