Enea Series Detectors

Addressable analog detectors. Thanks to modern technologies based on the latest generation of microprocessors, they represent the most advanced fire detection systems available today.

ED100_Contexts02

ED100 optical smoke detector: adjustable sensitivity and high reliability with false alarm protection

The ED100 smoke detector from the Enea series utilizes the Tyndall effect (light scattering) to providehighly accurate detection of particles generated by a fire. Its ability to respond quickly makes it ideal for environments where early detection is crucial. The optimized design of the detection chamber, the superior sealing, and the 500-micron insect screen ensure excellent protection against false alarms. Furthermore, the detector’s sensitivity can be easily adjusted to different operating conditions, thanks to four selectable levels (0.08, 0.10, 0.12, 0.15 dB/m).

ED200 heat detector: versatile, precise and ideal for demanding environments

The Enea ED200 series detector is designed to ensure accurate temperature detection, even in conditions where smoke can cause false alarms. It can be configured in various operating modes (A1R, B, A2S, BR) with fixed thresholds between 58°C and 72°C and thermal velocity measurement capabilities. This versatility makes it particularly suitable for industrial environments, professional kitchens, or mechanical rooms, where optical detection may prove ineffective. The ED200 represents a reliable solution for thermal monitoring of sensitive areas.

ED200_Contexts02
ED300_Contexts02

ED300 dual-technology detector: enhanced safety and false alarm prevention

The Enea ED300 model combines optical smoke detection with thermal detection, delivering high performance in any type of fire scenario. With five operating modes selectable from the control panel (PLUS, OR, AND, SMOKE ONLY, TEMPERATURE ONLY), the device adapts perfectly to a variety of safety requirements. PLUS mode ensures maximum sensitivity for critical fire outbreaks, while AND mode offers maximum rejection of false alarms. The ED300 is the ideal choice for environments where high standards of reliability and operational flexibility are required.

Technical specifications

ED100ED100/BED200ED200/BED300ED300/B
Power supply voltage10 - 30 Vdc10 - 30 Vdc10 - 30 Vdc10 - 30 Vdc10 - 30 Vdc10 - 30 Vdc
Current draw during standby90 μA90 μA90 μA90 μA90 μA90 μA
Current draw during alarmMax 40 mAMax 40 mAMax 40 mAMax 40 mAMax 40 mAMax 40 mA
Adjustable sensitivity0.08 - 0.10 - 0.12 - 0.15 dBm0.08 - 0.10 - 0.12 - 0.15 dBm0.08 - 0.10 - 0.12 - 0.15 dBm0.08 - 0.10 - 0.12 - 0.15 dBm0.08 - 0.10 - 0.12 - 0.15 dBm0.08 - 0.10 - 0.12 - 0.15 dBm
Operating temperature-5° ... +40°C-5° ... +40°C-5° ... +40°C-5° ... +40°C-5° ... +40°C-5° ... +40°C
Height (including base)46 mm46 mm54 mm54 mm54 mm54 mm
Diameter110 mm110 mm110 mm110 mm110 mm110 mm
Weight (with base)160 g160 g160 g160 g160 g160 g
Weight (without base)90 g90 g90 g90 g90 g90 g
ColourWhiteBlackWhiteBlackWhiteBlack

Download documentation

lock
keyboard_arrow_down Installation Manual - Materials (8)
lock
keyboard_arrow_down Data Sheet - Materials (18)
keyboard_arrow_down Certificate of Analysis (CoA) - Materials (4)
keyboard_arrow_down Certificate of Conformity (CoC) - Materials (2)
keyboard_arrow_down Certificate of Performance (CoP) - Materials (6)
keyboard_arrow_down EU Declaration of Conformity - Materials (18)
keyboard_arrow_down (EU) Declaration of Performance - Materials (6)
lock
keyboard_arrow_down DWG/DXF drawings - Materials (4)
lock
keyboard_arrow_down PDF Drawings - Materials (4)
Materials (70)

Interested in these products?

Request more information

Download the Fire & Safety Catalog